ECUMASTER PMU-16 · PDM · power distribution

ECUMASTER PMU-16 wiring: pinout, outputs and setup

The PMU-16 is a power distribution module (PDM): one box that replaces the fuse box and the relays. The battery feeds it through a single M6 stud, and each of its 16 outputs is an electronic switch with its own current limit, so a short trips that one output instead of a fuse, and it can be reset from the software.

Open the editor · ▶ Run the live demo

What the PMU-16 can switch

PMU-16
Outputs16: 10 × 25 A and 6 × 15 A continuous
Total current150 A continuous, through the M6 battery stud
ProtectionOvercurrent and overheating on every output, current limit set in 100 mA steps
Inputs16 analog, 0–5 V, 10-bit, software pull-up or pull-down 10 kΩ
Sensor supply+5 V, 500 mA, monitored
CAN2 × CAN 2.0 A/B, 125 to 1000 kbps; up to 2 ECUMASTER keypads
Supply voltage6–22 V
LoggingPMU-16 DL only: 256 MB, up to 500 Hz
Size, weight131 × 112 × 32.5 mm, 370 g

Outputs can be paired when one load needs more than a single output carries. Output O8 is the wiper output with a braking feature, so the wipers stop in park instead of coasting.

PMU-16 pinout: the 39-pin connector

PinFunction
1Output O13
2Output O12
3Output O11
4Output O10
5Output O9
6Input A9
7+12V sw
8Input A14
9Output O8 (wipers)
10Output O7
11Output O6
12Output O5
13Output O4
14Output O14
15+5V output
16Input A2
17Input A4
18Input A6
19Input A8
20Input A11
21Input A13
22Input A16
23CAN1H (PC comm)
24CAN2H
25Ground
26Output O3
27Output O15
28Output O16
29Input A1
30Input A3
31Input A5
32Input A7
33Input A10
34Input A12
35Input A15
36CAN1L (PC comm)
37CAN2L
38Output O1
39Output O2
M6+12V battery (stud, max 150 A)

How to wire it

PDM or fuses and relays?

For a road car with a handful of added circuits, a fuse box with relays is cheaper and any workshop can fix it. A PDM earns its place when there are many loads and you want logic: the fan switched by coolant temperature read from the ECU over CAN, the fuel pump primed for two seconds and then cut unless the engine turns, a soft start on a big fan, and a live current reading for every circuit, which makes a failing pump visible before it stops.

It also saves weight and wiring in a race car: no fuse box, no relay bank, one supply cable and a harness that only carries signals to the switches.

See also: Fuse box wiring · Motorsport harness design

Draw a PMU-16 harness in WireForge

  1. Add an ECU Module and choose ECUMASTER PMU-16: you get the 39-pin connector and the battery stud.
  2. Connect the battery to the stud through a main fuse, ground pin 25 and the ignition to pin 7.
  3. Set each output you use to “Output → +12 V (high-side)” and connect its load; add the switches on the inputs.
  4. Simulate: every output shows its current, so you can check the 25 A and 15 A limits before you build.

Questions

How much current can a PMU-16 output carry?

Ten outputs are rated 25 A and six are 15 A continuous; the whole unit takes 150 A continuous through the battery stud. Outputs can be paired for a bigger load.

Does a PMU-16 need fuses?

Not on its outputs: each one has its own current limit and overheat protection. The supply cable from the battery to the stud still needs a main fuse or breaker near the battery.

What is the difference between PMU-16 and PMU-16 DL?

The DL version adds a 256 MB data logger recording up to 500 Hz. The pinout is the same.

Can the PMU-16 run wipers?

Yes. Output O8 is the dedicated wiper output, with a braking feature so the wipers stop in their park position.

More guides

WireForge.pro · Українська · Polski · Deutsch · Español · Português (Brasil) · Français · Italiano · Türkçe · Čeština · Română · Русский