ECUMASTER PMU-16 · PDM · power distribution
ECUMASTER PMU-16 wiring: pinout, outputs and setup
The PMU-16 is a power distribution module (PDM): one box that replaces the fuse box and the relays. The battery feeds it through a single M6 stud, and each of its 16 outputs is an electronic switch with its own current limit, so a short trips that one output instead of a fuse, and it can be reset from the software.
Open the editor · ▶ Run the live demo
What the PMU-16 can switch
| PMU-16 | |
|---|---|
| Outputs | 16: 10 × 25 A and 6 × 15 A continuous |
| Total current | 150 A continuous, through the M6 battery stud |
| Protection | Overcurrent and overheating on every output, current limit set in 100 mA steps |
| Inputs | 16 analog, 0–5 V, 10-bit, software pull-up or pull-down 10 kΩ |
| Sensor supply | +5 V, 500 mA, monitored |
| CAN | 2 × CAN 2.0 A/B, 125 to 1000 kbps; up to 2 ECUMASTER keypads |
| Supply voltage | 6–22 V |
| Logging | PMU-16 DL only: 256 MB, up to 500 Hz |
| Size, weight | 131 × 112 × 32.5 mm, 370 g |
Outputs can be paired when one load needs more than a single output carries. Output O8 is the wiper output with a braking feature, so the wipers stop in park instead of coasting.
PMU-16 pinout: the 39-pin connector
| Pin | Function |
|---|---|
| 1 | Output O13 |
| 2 | Output O12 |
| 3 | Output O11 |
| 4 | Output O10 |
| 5 | Output O9 |
| 6 | Input A9 |
| 7 | +12V sw |
| 8 | Input A14 |
| 9 | Output O8 (wipers) |
| 10 | Output O7 |
| 11 | Output O6 |
| 12 | Output O5 |
| 13 | Output O4 |
| 14 | Output O14 |
| 15 | +5V output |
| 16 | Input A2 |
| 17 | Input A4 |
| 18 | Input A6 |
| 19 | Input A8 |
| 20 | Input A11 |
| 21 | Input A13 |
| 22 | Input A16 |
| 23 | CAN1H (PC comm) |
| 24 | CAN2H |
| 25 | Ground |
| 26 | Output O3 |
| 27 | Output O15 |
| 28 | Output O16 |
| 29 | Input A1 |
| 30 | Input A3 |
| 31 | Input A5 |
| 32 | Input A7 |
| 33 | Input A10 |
| 34 | Input A12 |
| 35 | Input A15 |
| 36 | CAN1L (PC comm) |
| 37 | CAN2L |
| 38 | Output O1 |
| 39 | Output O2 |
| M6 | +12V battery (stud, max 150 A) |
How to wire it
- Battery positive to the M6 stud with a cable sized for the total load and a main fuse or breaker close to the battery. This feed carries everything the outputs switch.
- Ground: pin 25. A PDM switches the positive side, so every load still needs its own good ground.
- +12V sw (pin 7) is the ignition signal: it wakes the PMU-16.
- Each load goes on one output: fuel pump, fans, ECU feed, injectors and coils feed, lights, horn, wipers on O8.
- Switches and sensors go to the inputs A1–A16, wired to ground; the +5 V output (pin 15) feeds sensors that need it.
- CAN1 (pins 23/36) is also the PC connection; the ECU, dash or keypad can share it or use CAN2 (pins 24/37).
PDM or fuses and relays?
For a road car with a handful of added circuits, a fuse box with relays is cheaper and any workshop can fix it. A PDM earns its place when there are many loads and you want logic: the fan switched by coolant temperature read from the ECU over CAN, the fuel pump primed for two seconds and then cut unless the engine turns, a soft start on a big fan, and a live current reading for every circuit, which makes a failing pump visible before it stops.
It also saves weight and wiring in a race car: no fuse box, no relay bank, one supply cable and a harness that only carries signals to the switches.
See also: Fuse box wiring · Motorsport harness design
Draw a PMU-16 harness in WireForge
- Add an ECU Module and choose ECUMASTER PMU-16: you get the 39-pin connector and the battery stud.
- Connect the battery to the stud through a main fuse, ground pin 25 and the ignition to pin 7.
- Set each output you use to “Output → +12 V (high-side)” and connect its load; add the switches on the inputs.
- Simulate: every output shows its current, so you can check the 25 A and 15 A limits before you build.
Questions
How much current can a PMU-16 output carry?
Ten outputs are rated 25 A and six are 15 A continuous; the whole unit takes 150 A continuous through the battery stud. Outputs can be paired for a bigger load.
Does a PMU-16 need fuses?
Not on its outputs: each one has its own current limit and overheat protection. The supply cable from the battery to the stud still needs a main fuse or breaker near the battery.
What is the difference between PMU-16 and PMU-16 DL?
The DL version adds a 256 MB data logger recording up to 500 Hz. The pinout is the same.
Can the PMU-16 run wipers?
Yes. Output O8 is the dedicated wiper output, with a braking feature so the wipers stop in their park position.